Cisco UCS B420 M4 Note d'installation et d'entretien - Page 34

Parcourez en ligne ou téléchargez le pdf Note d'installation et d'entretien pour {nom_de_la_catégorie} Cisco UCS B420 M4. Cisco UCS B420 M4 38 pages. Blade server

Cisco UCS B420 M4 Note d'installation et d'entretien
Enabling the Trusted Platform Module
c) Install the TPM to the TPM socket on the server motherboard and secure it using the one-way screw that
is provided. See the figure below for the location of the TPM socket.
d) Return the blade server to the chassis and allow it to be automatically reacknowledged, reassociated, and
recommissioned.
e) Continue with enabling TPM support in the server BIOS in the next step.
Figure 19: TPM Socket Location
1

Step 2

Enable TPM Support in the BIOS.
Note
If TPM support was disabled for any reason, use the following procedure to enable it.
a) In the Cisco UCS Manager Navigation pane, click the Servers tab.
Cisco UCS B420 M4 Blade Server Installation and Service Note
32
Front of server
TPM 2.0 support is enabled by default in Cisco UCS Manager Release 3.1(2) and Release 2.2(8)
and later BIOS policy. If your Cisco UCS Manager Release 3.1(2) or Release 2.2(8) and later BIOS
policy is using the default setting and TPM 2.0 support is already enabled, skip this procedure and
go to the next step.
TPM 1.2 support is disabled by default in Cisco UCS Manager Release 2.2(5) and later BIOS policy.
If your Cisco UCS Manager Release 2.2(5) and later BIOS policy is using the default setting and
TPM 1.2 support is already enabled, skip this procedure and go to the next step.
2
TPM socket on
motherboard
Servicing the Blade Server