8. Remove one screw(CBB, 3x12) securing the motor, and remove the
motor.
9. Loosen a screw(CBS, M3x6) securing the "Tension Lever
Assembly" to "Motor Frame", move "Lever Assembly, Tension" to
the arrowed direction, releasing the tension of the timing belt of CR
motor. Then, remove "Timing Belt B".
10. Remove 3 "Shaft, Damper, CR" and remove "CR Motor" from "Motor
Frame".
CBS(M3x6)
Figure 3-7. CR Motor Assembly Removal
Disassembly and Assembly
CBB(3x12)
CR Motor Assembly
Disassembly and Assembly

3.1.5 Lamp Assembly Removal

1. Remove carriage assembly. (Refer to Service Manual of GT-9500)
2. Remove 2 screws(CB, M3x6) securing "Cover, Rear, Carriage" to
"Carriage Assembly", and remove "Cover, Rear, Carriage".
3. Remove 3 screws (CB, M 3x6) securing "Cover, Carriage" to
"Carriage Assembly", and remove "Cover, Carriage".
One screw(CB, M3x8) under "Cover,
Rear, Carriage".
CB(M3x6)
Figure 3-8. Carriage Cover Removal