Eckerle Gotec SP32/02-80-E Informations techniques - Page 4

Parcourez en ligne ou téléchargez le pdf Informations techniques pour {nom_de_la_catégorie} Eckerle Gotec SP32/02-80-E. Eckerle Gotec SP32/02-80-E 8 pages. Oil lifters

Technical Features
ELECTRICAL
TYPE
Voltage
Frequency
SP32
230 V
50 Hz
02-80
1. Description :
The SP32 02 suction pump incorporates an electromagnetic pump with
oscillating piston, a float (motor ignition and shutdown), a safety device
for overflowing, a thermal safety device, a low safety device, and a leak
detection float in the drip tray, all controlled by an electronic circuit.
The motor is protected by a fine filter that is built into a metal part.
Two additional electronic safety measures also protect the engine in
the event of the cistern being empty or leaking. The pump function is
secured by a drip tray and is delivered ready-made, with cable and pipe
fittings for ø 6/8 mm (ø 8/10 mm on request) copper tubes all included.
Maintenance is limited to a periodic cleaning of the suction filter.
Our pump conforms to standards regulations EN 12514.
2. Usage :
Suction pump SP32 02-80 is used as an intermediate tier in the feeding
of automatic oil burners. The pump sucks in the fuel oil until it reaches
a maximum level of 7m and fills its own tank with a capacity of 7.3 litres
per automatic cycle. There must not be a backflow preventer valve in the
suction pipe. With the tank being open, no purging system is required.
The oil burner can be above or below the pump (see examples). When
the burner is above the pump, the total height of the suction pipe in the
oil burner's cistern can reach 9m.
3. Caution during installation:
Before installing the pump, ensure the safety packaging is removed
as follows: remove the pump from the packaging, remove the lid by
loosening the 3 screws (10), take off the protective plastic caps on the
pipe fittings (15).
4. Wall Mounting
Accessibility between the lid and the pump must always be observed. It
must be located at least 30cm above the highest oil heater. Make sure
that this is straight (±2° tolerance). The pump must always be at least
30 cm above the highest level of the cistern. The oil lifter may only be
operated in dry and well-ventilated rooms
5. Pipe Installation
All the pipes (both suction and delivery) must be in ø 8/10 mm copper
tubes. If they are in ø6/8 mm tubes, replace the pump's ø 8/10 mm (15)
pipe fittings with ø6/8 mm pipe fittings, which are provided in the acces-
sories bag. Ensure the pipe fittings are airtight when assembled. The
pipe junctions are bit type sleeves. Avoid throttling and closed angles.
Do not use hemp to seal the pipe fittings. All this must be carried out in
accordance with legal regulations.
Order of Assembly
1. Assemble the packing boxes (14) without lock nuts on
the tubes (3 & 4).
2. Pass the tubes (3 & 4) through the purpose-made holes in the tank.
3. Assemble the packing box lock nuts (14) on the tubes (3 & 4)
as well as the nuts and bolts of the pipe fittings (15).
4. Connect the tubes (3 & 4) and tighten the pipe fittings (15).
5. Assemble the packing boxes (14) on the tank and then tighten all the
nuts
Power
Fuse
80 W
0,5 A
15
HYDRAULIC
Output function
for suction height
7 m
20 l/h
4 m
55 l/h
6. Electrical Installation
The power supply must be 230 V/50 Hz and grounded. The SP32 02
pumps are delivered with cable and power plug. A fast 0.5 A 20x5 fuse is
built into the electronic circuit.
Solenoid valve version
Do not forget to connect the solenoid valve to the oil burner before com-
missioning. This solenoid valve, which is normally closed, is controlled
by the oil burner. As soon as this stops, the solenoid valve's
power supply must be interrupted in order to avoid a possible siphonage
effect.
Key :
1. SP32 02-80 pump
3. Suction pipe
5. LCD Display
7. Power plug
9. Stove/Burner
11. Lid
mechanical anti-siphoning
14. Compression gland
ø8/10 mm or ø 6/8 mm
17. Fill opening
VERBRAUCHER :
Brenner über der
SP32-02
7. Using the SP32 02-80 pump
Use heating additive-free oil or kerosene. Check if the fuel oil in the cis-
tern is clean. Do not use additives, as those already incorporated are the
correct amounts to deal with improved combustion, ageing and resistan-
ce to the cold. Any further additions could quickly damage the pump.
Caution !
Upon ignition, a 10-minute delay prevents the pump from running
without liquid; the option of filling the suction pipe with a suction hand
pump must be considered if this pipe is long or part of a bigger section.
Start-up
1° Insert the plug (7) into the socket. When the display (5) shows 8. the
pump is powered.
2° Open the shut-off valve (8), and open the furnace valve
3° Press the switch (6), the LCD (5) will then show 0,1,2 and 3 in suc
cession.
- 4 -
GB
MECHANICAL
Reseve-
Gewicht netto
Storage
7,3 l
7 Kg
2. Cistern
4. Feeding pipe
6. Switch
8. Shut-of valve
10. Screw of the lid
12. Electro-valve or
13. Lid of the cistern
15. Coupling
16. Drip tray
18. Float
VERBRAUCHER :
Brenner unter der
SP32-02