The following steps guide you to the correct settings of your MCVEVP.
2.1 Apply Correct Jumper Settings
Pin 1 of each header is marked with a yellow dot in the picture.
1. place jumpers on P25 and P29 to activate the UART0 interface
2. leave jumper P32 open to select eMMC boot mode for MCV
3. place jumper to connect pin 1 and pin 2 on connector JP4 to connect VCCIO3B4A to 3.3V
4. Insert the MCV SoM into the Samtec connectors on MCVEVP