Ariston microSYSTEM 15 RFFI Manuel d'instructions d'installation
2.4
S
A
ITING THE
PPLIANCE
132
132
C
E
F
. 2.1
IG
2.7
M

OUNTING THE

2.8
E
C
LECTRICAL
F
. 2.2
IG
This appliance is not suitable for outdoor installation.
The type C appliances (in which the combustion circuit, air vent intake and
combustion chamber are air-tight with respect to the room in which the
appliance is installed) can be installed in any type of room.
Secondary ventilation is not required with this boiler. The boiler must be installed on
a solid, non-combustible, permanent wall to prevent access from the rear.
60 mm
Fasten the boiler in place using the template and anchors supplied with the unit. It is
A
PPLIANCE
highly recommended that a spirit level be used to position the boiler so that it is
perfectly level.
For additional information, please consult the instructions contained in the
connection kit and the flue kit.
For safety purposes, have a competent person carefully check the electrical system
ONNECTION
in the property, as the manufacturer will not be held liable for damage caused by the
failure to earth the appliance properly or by anomalies in the supply of power. Make
sure that the residential electrical system is adequate for the maximum power
absorbed by the unit, which is indicated on the rating plate. In addition, check that the
section of cabling is appropriate for the power absorbed by the boiler.
I
MPORTANT
In the event that the power supply cord must be changed, replace it with one with the
same specifications. Make the connections to the terminal board located within the
control panel, as follows:
- The yellow-green wire should be connected to the terminal marked with the "
symbol;
2.5
O
L
:
EGEND
A
= Central Heating Flow (3/4")
C
= Gas Inlet (3/4")
E
= Central Heating Return (3/4")
mm = Clearances
450 mm
2.6
C
In order to allow for access to the interior of the boiler for
maintenance pur poses, the boiler must be installed in
compliance with the minimum clearances indicated in F
The boiler operates with alternating current, as indicated in the
technical information table in section 7, where the maximum
absorbed power is also indicated. Make sure that the
connections for the neutral and live wires correspond to the
N
indications in the diagram. The appliance electrical connections
L
are situated on the reverse of the control panel under the
E
inspection cover (see the ser vicing manual for fur ther
information)
!
6
D
VERALL
IMENSIONS
LEARANCES
. 2.1
IG
"