Whirlpool 9763375 Instructions d'installation et manuel d'utilisation et d'entretien - Page 4
Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Whirlpool 9763375. Whirlpool 9763375 28 pages. 30" (76.2 cm) and 36" (91.4 cm) wall-mount canopy range hood
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed:
■
level
■
drill with 1 " (3 cm),
" (9.5 mm),
" (3 mm) drill bits
■
pencil
■
wire stripper or utility knife
■
measuring tape or ruler
■
pliers
■
caulking gun and weatherproof caulking compound
■
duct tape
■
jig saw or keyhole saw
■
flat blade screwdriver
■
metal snips
■
Phillips screwdriver
Parts needed:
■
1 x
" conduit
■
1 wall or roof cap
■
metal vent system
■
2 charcoal filters – for non-vented (recirculating)
installations only
Parts supplied:
Remove parts from packages. Check that all parts were included.
■
hood canopy assembly with ventilator and light bulbs installed
■
deflector for non-vented (recirculating) installations
■
plastic transition with back draft dampers installed
■
Installation Instructions and Use & Care Guide
■
filter(s) – depending on model and size
■
screws and drywall anchors
■
2 mounting hooks
■
vent cover support bracket
■
mounting template
■
2 piece vent cover
■
rubber tape
4
INSTALLATION REQUIREMENTS
" (2.75 mm) and
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) installations see "Non-vented
(recirculating) installations" in "Prepare Mounting Location"
section.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
Product Dimensions
8"
(20.3 cm)
6 "
(17.1 cm)
upper vent
cover
lower vent
cover
20
"
(51.3 cm)
NOTE: For reduced ceiling height vented and non-vented (recirculating)
installations, only the upper vent cover, which is 26" (66.0 cm), is used.
9 " (24.4 cm) min.
26" (66.0 cm) max.
26" (66.0 cm)
min.
42 " (107.6 cm)
16 "
max.
(42.5 cm)
9 "
(24.1 cm)
30" (76.2 cm) or
36" (91.4 cm)