To wire through rear wall:
Mark a line 7½" (19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is ¾" (1.9 cm) from
underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole
through wall at this point.
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65 " (167.3 cm) and
62 " (158.4 cm) or
" (3.2 mm) and 3 " (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(3.2 mm)
"
(9.2 cm)
8
" (1.9 cm)
7 "
(19 cm)
Centerline
*1 / " (3.8 cm)
*5 / "
5 / "
(14 cm)
(13.3 cm)
5 / "
(13.3 cm)
Centerline
5 "
(13.3 cm)
Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System
Roof Venting
To make a 7 " (18.4 cm) circle on the underside of the cabinet
top and bottom:
1. Mark a centerline on the underside of the cabinet bottom.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 7 " (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 7 " (18.4 cm) diameter
opening.
5. Repeat steps 1-4 for the underside of the top of the cabinet.
*5"
(12.7 cm)
*From wall, not
cabinet frame
Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 7" (17.8 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on
the underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5 / "
(14 cm)
*From wall, not cabinet frame
7 / " (18.4 cm) diam.
cabinet cutouts
*1 / " (3.8 cm)
5 / "
(13.3 cm)
5 / "
(13.3 cm)