Whirlpool W10240580A Kurulum Talimatları ve Kullanım ve Bakım Kılavuzu - Sayfa 8

Havalandırma Davlumbazı Whirlpool W10240580A için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım ve Bakım Kılavuzu indirin. Whirlpool W10240580A 28 sayfaları. 30" (76.2 cm) and 36" (91.4 cm) range hood

Whirlpool W10240580A Kurulum Talimatları ve Kullanım ve Bakım Kılavuzu
To wire through rear wall:
Mark a line 7½" (19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is ¾" (1.9 cm) from
underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole
through wall at this point.
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65 " (167.3 cm) and
62 " (158.4 cm) or
" (3.2 mm) and 3 " (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(3.2 mm)
"
(9.2 cm)
8
" (1.9 cm)
7 "
(19 cm)
Centerline
*1 / " (3.8 cm)
*5 / "
5 / "
(14 cm)
(13.3 cm)
5 / "
(13.3 cm)
Centerline
5 "
(13.3 cm)
Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System
Roof Venting
To make a 7 " (18.4 cm) circle on the underside of the cabinet
top and bottom:
1. Mark a centerline on the underside of the cabinet bottom.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 7 " (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 7 " (18.4 cm) diameter
opening.
5. Repeat steps 1-4 for the underside of the top of the cabinet.
*5"
(12.7 cm)
*From wall, not
cabinet frame
Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 7" (17.8 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on
the underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5 / "
(14 cm)
*From wall, not cabinet frame
7 / " (18.4 cm) diam.
cabinet cutouts
*1 / " (3.8 cm)
5 / "
(13.3 cm)
5 / "
(13.3 cm)