Versa'larm
2-Zone Alarm - Model VA02A | Sump and Flood
Operation, Maintenance and Installation Manual
Introduction of Installation
Safety Guidelines
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE INSTALLING OR WORKING ON THE PRODUCT.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC.
DO NOT USE IN EXPLOSIVE ATMOSPHERES.
3. ALARM PANEL MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS CONSULT FACTORY.
Description of Operation
The 2-Zone Sump and Flood Versa'larm™ alarm panel is powered by 120 VAC coming from standard wall outlets and is
transformed to 9-11.1 VDC. Installing a 9 Volt battery provides battery backup during power outages. The power LED
(green) will illuminate when powered.
When a switch (signaling device) contact "closes" the buzzer will annunciate, alarm LED (red) will illuminate for the zone the
closedswitch is connection to (Sump and/or Flood), and the built in auxiliary contacts will be activated.
Pressing the "Alarm Silence" pushbutton will silence the buzzer and the LED(s) (red) remain on. When the alarm condition
is cleared, the system automatically resets itself for the next alarm cycle.
Tools, Supplies and Requirements for Installation - Not Included
1. Phillips screw driver
2. (Qty 2) #6 self tapping screws
3. Access to 120 VAC power receptacle
4. Optional - Plastic anchors (#8; Qty 2) if mounting to sheet rock
5. Optional - 9V battery (used for battery backup during power outages)
6. Optional - Wire stripper (used if you need to strip wire to connect to a BAS or SCADA system)
7. Optional - Needle nose pliers if using auxiliary contacts
Alarm Systems
Control Panels
Alderon Industries - Hawley, MN | 218.483.3034 | [email protected] | alderonind.com
™
Before proceeding with the installation or operation of the product, read all
instructions thoroughly, as well as complying with all federal, state and local
codes, regulations, and practices. The product must be installed by qualified
personnel familiar with all applicable local electrical and mechanical codes.
Refer to the National Electrical Code (NFPA 70). Failure to properly install and
test this product can result in personal injury or equipment malfunction.