Features
Refer to the illustration below to reference the feature descriptions provided.
1
6
(1) VertiMAC™ Pump Switch Housing - Magnetically
activated switching mechanism encapsulated in epoxy to
ensure a waterproof switch.
(2) Actuator Pin - Connects the actuator rod to the pump
switch housing to ensure proper activation of the switching
mechanism.
(3) Actuator Rod - Activates or deactivates the mechanism
inside the pump switch housing as the float rises or lowers
on the rod.
(4) Float - Slides up and down the actuator rod to turn the
pump on and off.
(5) Rubber Grommet - Placed on the actuator rod at the
determined location for desired pump differential.
VertiMAC™ Pump Switch - USER GUIDE
6
9
2
7
3
4
5
(6) Pipe Clamp Bracket - Pre-installed, attaches to the pump
switch housing and used to mount the VertiMAC™ pump
switch to a pipe.
(7) Stainless Steel Pipe Clamp - Attaches to the pipe clamp
bracket and secures the VertiMAC™ pump switch to a pipe at
the desired mounting location.
(8) Pump Switch Power Cable (not shown) - Available in
120VAC or 240VAC, bare lead (no plug) or piggyback plug, 13
Amp models.
(9) QR Code - Scan code which directs you to alderonind.com
where additional information can be found for the VertiMAC™
pump switch.