INSTALLER OPTIONS

Option
Description
01
Equipment Type
02
Reversing Valve
(Only displayed if HP selected)
03
Compressor Stages
04
Heating Stages
05
Fan Operation.
(Only displayed if GE selected)
06
Compressor Minimum Off Time (minutes).
07
Gas Minimum Off Time (minutes).
08
Minimum Run Time (minutes).
09
On-Off Temperature Differential
o
0 Cooling On 1 above setpoint, Off at setpoint. Heating On1 below setpoint, Off at setpoint.
o
1 Cooling On 1 above setpoint, Off .5 below setpoint. Heating On1 below setpoint, Off .5 above setpoint.
o
2 Cooling On 1 above setpoint, Off 1 below setpoint. Heating On1 below setpoint, Off 1 above setpoint.
10
Smart Recovery.
11
Vacant Heating Setpoint.
12
Vacant Cooling Setpoint.
Calibrate Living Area Sensor
13
14
Calibrate Sleeping Area Sensor.
15
Airflow Update Time
Night Level LCD Backlight
16
17
Airflow Control On or Off
18
Enable User Airflow Control
Up Stage Time
19
20
Maximum Airflow in Heating to the Sleeping Area.
21
Maximum Airflow in Cooling to the Sleeping Area.
22
Maximum Airflow in Heating to the Living Area.
Maximum Airflow in Cooling to the Living Area.
23
24
Maximum Temperature Difference Between
Sleeping and Living area.
Factory Restore
25
ACCESSING INSTALLER OPTIONS
To access the Installer Options,
key for 7 seconds until the first Option appears on the screen.
Sleeping
Airflow %
Living
Day
Tu
AM
MENU
MODE
The hidden BACK key can be
used to return to previous options.
Press the touchscreen with your fingertip only, using a firm
!
touch. Do not use a sharp object such as a pen or pencil.
!
The NEXT key is used to display the next option.
The ENTER key is used to save options and return to normal
!
thermostat operation.
The hidden BACK key is used to return to previous options
!
and is located to the left of the NEXT key.
o
o
TOUCH
and
HOLD
the hidden Enter
Cool
Set To
Schedule
Living
COOL
SYSTEM
AUTO
FAN
TOUCH
and
HOLD
this key for 7 seconds
to access the Installer Options.
Display
Range
GE or HP
rEV
o or b
Cpr
0 or 1 (GE), 0 to 2 (HP)
Htg
0, 1 or 2
Fan
GA(Down) or EL(Up)
Cot
0 to 9
0 to 9
HOt
r n t
0 to 9
o
O O
0, 1 or 2
o
o
o
S r
0n(Up) or Off(Down)
V A C
+ Heat
44 to 75
V A C
+ Cool
74 to 95
C A L
+/- 5
C A L
+/- 5
A F t
1 to 20 minutes
+ Night
BL
On(Up) or Off(Down)
AFC
On(Up) or Off(Down)
UAC
On(Up) or Off(Down)
USt
5 to 30 minutes
HAF+Heat
100 to 160%
CAF+Cool
100 to 160%
HAF+Heat
100 to 160%
CAF+Cool
100 to 160%
diF
0 to 10
Fr
No(Next or Enter) or Yes(UP Key then ENTER)
01 Selecting the Equipment Type
This option is used to select gas/electric or heat pump equipment.
Use the UP/DOWN keys to
select gas/electric (GE) or heat
pump (HP).
Touch NEXT or ENTER.
02 Reversing Valve
This option is used to select an O or B type reversing valve.
Use the UP/DOWN keys to
select o for O-Type or b for B-
Type.
Touch NEXT or ENTER.
03 Setting the Compressor Stages
This option is used to set the number of compressor stages.
Use the UP/DOWN keys to set
0 or 1 stage.
Touch NEXT or ENTER.
5
Default
Gas/Electric
O
1 (GE), 2 (HP)
1
GA
2
0
2
1
o
o
Off
65
80
0
0
2
On
On
Off
10
150%
140%
150%
140%
2
Option
NEXT
ENTER
Factory Default: GE. Range: GE or HP
(Only displayed if HP selected)
Option
NEXT
ENTER
Factory Default: O. Range: o or b
Option
NEXT
ENTER
Factory Default: 1 . Range: 0, 1 or 2