16 Night Level LCD Backlight
The LCD has a low level backlight that can be used as a night light.
Use the
UP
key to turn the low
level backlight ON or touch the
DOWN
key to turn OFF.
Touch
NEXT
or
ENTER.
17 Airflow Control, On or Off
This option turns the automatic airflow control on or off. If off, the
dampers fully open, nighttime airflow options are disabled and airflow is
no longer displayed on the thermostat.
Use the
UP
key to select ON
for airflow control or touch the
DOWN
key to select OFF to
disable airflow control.
Touch
NEXT
or
ENTER
.
If Airflow Control was off and is now
being turned on, the Nighttime Airflow
option needs to be turned on using
the User Options.
18 Enable USER Airflow Control
Homeowners with an unusual work schedule, home office, etc. may
want to use this option. When turned On, this option enables the user to
turn off automatic airflow control in the User Options. Airflow is adjusted
by the homeowner. Nighttime Airflow option is still enabled but can be
turned off using the User Options.
Use the
UP
key to select ON to
enable the user to turn off
automatic airflow control in the
user options.
Touch
NEXT
or
ENTER.
19 Upstaging Time
Use the
UP/DOWN
keys to set
the time at which second stage
heating or cooling is activated.
Touch
NEXT
or
ENTER.
Factory Default: 10 minutes. Range: 5 to 30 minutes
For options 20 - 23, use the installer test o
determine the max
imum allowable airflow.
20 Maximum Airflow in Heating to Sleeping Area
Use the
UP/DOWN
keys to
select the maximum allowable
airflow in heating to the
sleeping area.
Touch
NEXT
or
ENTER
.
Factory Default: 150%. Range: 100% to 160%.
Option
Night
NEXT
ENTER
Factory Default: On. Range: On or Off.
Sleeping
Option
Airflow %
Living
NEXT
ENTER
Factory Default: On. Range: On or Off.
Option
NEXT
ENTER
Factory Default: Off. Range: On or Off.
Option
NEXT
ENTER
n pages 7-8 to
Sleeping
Option
Heat
Airflow %
NEXT
ENTER
21 Maximum Airflow in Cooling to the Sleeping Area
Use the
UP/DOWN
keys to
select the maximum allowable
airflow in cooling to the
sleeping area.
Touch
NEXT
or
ENTER
.
22 Maximum Airflow in Heating to the Living Area
Use the
UP/DOWN
keys to
select the maximum allowable
airflow in heating to the living
area.
Touch
NEXT
or
ENTER.
23 Maximum Airflow in Cooling to the Living Area
Use the
UP/DOWN
keys to
select the maximum allowable
airflow in cooling to the living
area.
Touch
NEXT
or
ENTER
.
24 Maximum Temperature Differential
This is the maximum allowable temperature difference between the
sleeping and living area temperatures. When the temperature difference
is equal to or greater than the allowed differential, the airflow is adjusted.
Use the
UP/DOWN
keys to
select the maximum allowable
temperature difference between
the sleeping and living area
Touch NEXT
or
ENTER.
25 Factory Restore
WARNING! Factory Restore resets ALL settings.
To exit this option, touch
NEXT
To restore factory settings, touch the
Enter.
Option
NEXT
ENTER
7
Sleeping
Option
Airflow %
Cool
NEXT
ENTER
Factory Default: 140%. Range: 100% to 160%.
Option
Heat
Airflow %
Living
NEXT
ENTER
Factory Default: 150%. Range: 100% to 160%.
Option
Airflow %
Cool
Living
NEXT
ENTER
Factory Default: 140%. Range: 100% to 160%.
Option
NEXT
ENTER
o
Factory Default: 2 F.
Range: 0 to 10 F
or
ENTER, or the hidden Back key.
UP
key to display YES then touch
Option
NEXT
ENTER
o