Zanussi ZGG76524XA Manuel de l'utilisateur - Page 21

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Zanussi ZGG76524XA. Zanussi ZGG76524XA 45 pages. Zanussi cooktop user manual
Également pour Zanussi ZGG76524XA : Manuel de l'utilisateur (16 pages)

Zanussi ZGG76524XA Manuel de l'utilisateur
ELECTRICAL CONNECTION
Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
Always use a correctly installed shockproof
socket.
Make sure that there is an access to the mains
plug after the installation.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown (or
black) phase cable to the terminal
which has a letter "L". Keep the phase
cable connected at all times.

CONNECTION CABLE

To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H05V2V2-F T90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
BUILDING IN
min.
450 mm
min.
55 mm
30 mm
480 mm
min.
650 mm
560 mm
10 mm
3 mm
A. supplied seal
B. supplied brackets
CAUTION! Install the appliance only
on a worktop with flat surface.

POSSIBILITIES FOR INSERTION

The panel installed below the hob must be easy to
remove and let an easy access in case a technical
assistance intervention is necessary.
Kitchen unit with door
A
86 mm
86 mm
A
B
min 6 mm
21