Clarus Fusion Series Manuel du propriétaire - Page 4

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} Clarus Fusion Series. Clarus Fusion Series 20 pages. Treatment systems
Également pour Clarus Fusion Series : Manuel du propriétaire (20 pages)

Clarus Fusion Series Manuel du propriétaire
DATAPLATE
A dataplate similar to the one in Figure 5 is located on the blower
housing and the alarm panel. There is important information about
the Fusion
on the dataplate, such as the part number, model
®
number, serial number, and hydraulic capacity. Please make a note
of this information for future reference or in case you should need to
contact your Fusion
®
maintenance provider.
The contracting installer must mark the installed model number on
the dataplate, the blower housing and the alarm control panel.
ALARM PANEL
The Fusion
®
utilizes an alarm panel (see Figure 6) that is designed to
activate an audible buzzer and red beacon light on top of the panel if
there is a drop in air pressure, if a high water alarm condition occurs,
or if the blower does not cycle between recirculation and backwash
modes within the preset time. (Note: Alarm panel can only function
as long as there is electrical power supplied to the panel)
You may from time to time check the proper operation of the alarm
panel by toggling the black switch on the side of the panel to "test".
The buzzer will sound and the red beacon will light as long as you
hold the switch in the test position. Release the switch for normal
operation.
SYSTEM CARE
The Fusion
system is designed to continuously operate automatically with
®
little direct maintenance from the owner. Periodically, a check of the blower
area is recommended to ensure no debris obstructs the ventilation or intake
areas of the blower. Also, periodically test the control panel as outlined under
the alarm panel section. The owner should closely monitor the types and
amounts of substances and products used. Water use should also be closely
monitored to ensure proper operation of the Fusion
Periodically, more extensive maintenance must be performed. Your authorized
Fusion
®
maintenance provider will oversee this service. The name of the
maintenance provider can be recorded on the front of this document and should
also be located on the alarm panel. For more information see the Operation and
Maintenance section of the manual.
The owner should only perform minimal routine maintenance on the Fusion
such as clearing debris from around blower housing (leaves, snow, and grass
clippings). The Fusion
should also be protected from excessive weight such
®
as vehicular traffic. Trees and bushes should not be planted in close proximity
to the Fusion
. The Fusion
should be accessible to maintenance personnel
®
®
and the riser lids must never be buried.
HIGH USE WATER DEVICES
The draining of hot tubs and swimming pools into your Fusion
will cause hydraulic overloading and will impair the treatment efficiency.
Please drain these devices to another location. Contact your local
regulatory authorities or authorized Fusion
more information. The use of large capacity single fill and drain whirlpool
bathtubs may also cause hydraulic overloading of your Fusion
the use of these types of tubs.
FLOODING
If flooding of the Fusion
alarm panel is submerged, please disconnect power at the circuit breaker.
DO NOT try to reconnect power to either the blower or alarm panel once
it has been submerged. Immediately contact your authorized Fusion
maintenance provider to inspect the Fusion
panel. Your maintenance provider will repair or replace the components as
needed.
system.
®
®
system
maintenance provider for
®
. Please limit
®
occurs and the blower or the
®
®
, the blower, and the alarm
®
© Copyright 2020. All rights reserved.
4
Figure 5
F U S IO N TRE ATM EN T SY ST EM
ZF 450
ZF 800
MFG.DATE:
Manufacturer:
Clarus Environmental • 3649 Cane Run Road
Louisville, KY 40211 • 1-800-928-7867
B LO WER SER V I CE P ART S
COMPLETE BLOWER:
BLOWER DIAPHRAGM:
BLOWER FILTER:
Figure 6
FUSION
DATAPLATE
Figure 7
120 VAC L1
INCOMING N
POWER GND
®
BLOWER
BLOWER FOR ZF-450 AND ZF-800
LEAKY FIXTURES
It is very important to monitor all water fixtures in the home for leaks and
*FOR ILLUSTRATION PURPOSES ONLY*
drips and repair them immediately. Leaks can cause tremendous water
use and may hydraulically overload your Fusion
its treatment efficiency. Excessive water use may also overload your soil
absorption field and cause failure.
INTERMITTENT USE
The Fusion
system is designed to function even if wastewater does not
®
enter it for extended periods of time. The power to the blower must remain
on during this time for the system to function properly. Weekend use will
not harm the system as long as the blower is on. Should seasonal use
require a complete shut down of the property, then it is recommended that
the blower be turned off. It is important to start up the system in advance of
actual occupancy to allow for normal treatment to resume. Please contact
your authorized Fusion
maintenance provider for further information
®
concerning shut down and startup of the Fusion
your maintenance provider for the shut down and startup services.
450 GALLONS/DAY
®
800 GALLONS/DAY
Certified to
NSF - ANSI
Standard 40
®
toll free
P/N 5250-0050-A
P/N 152949-A
P/N 152950-A
RED BEACON
WARNING!
SILENCE/TEST
SWITCH
P/N
BUZZER
1 2 3 4 5 6 7 8
TB2
DISNF
ALARM
HIGH WATER
ALARM
REFER TO SCHEMATIC LOCATED IN
®
system and reduce
PANEL FOR INSTALLATION
®
. You may also contact
sk2649
GND LUG
sk2933