COOLING SYSTEM FILLING/DRAINING DEVICE
AC 1022 : "GRAVITY" DRAINING METHOD
(OPTION)
• Attach the drip tray rod to the back of the unit in the slot above the used fluid container
(Fig. 19).
Fig. 19
• Place the unit underneath the vehicle at the radiator (Fig. 20) and open the valve in the
bowl (Fig. 21) to allow the fluid to flow directly into the bowl.
You can then begin a conventional gravity drain procedure (bleed screw, hose removal).
Fig. 21