Abbey B06-071 Manuel d'installation - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Abbey B06-071. Abbey B06-071 4 pages. Rs232 to rs485 converter

RS-485 Connection and Termination
3
2
1
CN2
We recommend the use of three-core screened cable for linking the converter to any
IED(Intelligent Electronic Device), with the screen connected to the GND pin of the
converter only.
If the cable is of the two-core screened type, use the screen as the GND wire.
The use of 120Ω termination resistors at each end of a long cable run is also
recommended to reduce signal reflections. RS-485 communication at low data rates
and short cable lengths will normally work without them, but their presence causes
no problems so they are always recommended.
CN2
1
2
3
RS-485 Connection and Termination
If two or more IEDs are used, make sure they are set to different addresses. Also
check the IED documentation to confirm that the IEDs can be multi-dropped, and to
find the maximum allowable number and recommended cable length for each IED.
Isolation
The converter does not provide electrical isolation. Isolation is recommended and
should be provided by the RS-485 interface in each IED.
Stand-alone products can also provide isolation if there is none present on the IED.
IG-518-4-2012-Feb
Looking at the end of CN2, the pin
configuration is as follows:
Some manufacturers also refer to
Data+ as 'Data A', 'True Data', or 'non-Inverted Data' and
Data- as "Data B' or 'Inverted Data'.
Screened
Multi Core
IED 1
D+
D-
IG
Screened
Multi Core
Screen
2
Pin
Function
1
Data+ or A
2
Data- or B
3
GND
IED n
D+
D-
IG
B06-071 Installation Guide