ARO PE03P A0S Series Manuel de l'opérateur - Page 9

Parcourez en ligne ou téléchargez le pdf Manuel de l'opérateur pour {nom_de_la_catégorie} ARO PE03P A0S Series. ARO PE03P A0S Series 12 pages. 3/8” diaphragm pump

REMOTE HOOK-UP CONNECTIONS
TYPICAL REMOTE HOOK-UP WITH ENHANCED POSITIVE FEEDBACK SIGNAL CAPABILITY
Supply air.
Air pilot return - solenoid actuated 4-way valve.
PLC / Controller signal.
Pneumatic feedback signal from pump.
Pneumatic echo can be used to interrupt the PLC
signal and set alarm.
NOTE: Pump may not be short-stroked with this system.
Pneumatic-to-electric signal can send alarm to operating system.
Figure 8
PE03P-X-X-A0S (en)
Page 9 of 12