REMOTE HOOK-UP CONNECTIONS
TYPICAL REMOTE HOOK-UP WITH ENHANCED POSITIVE FEEDBACK SIGNAL CAPABILITY
Supply air.
Air pilot return - solenoid actuated 4-way valve.
PLC / Controller signal.
Pneumatic feedback signal from pump.
Pneumatic echo can be used to interrupt the PLC
signal and set alarm.
NOTE: Pump may not be short-stroked with this system.
Pneumatic-to-electric signal can send alarm to operating system.
Figure 8