Cable types and minimum thicknesses
Connection
Control panel power supply 230 V AC
Power supply to motor 230 V AC
Flashing light
Photocell transmitters
Photocell receivers
Command and safety device
Antenna
If cable lengths diff er from those specifi ed in the table, establish the cable sections depending on the actual power draw of the connected
devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products.
INSTALLATION
The following illustrations are just examples, in that the space available for fitting the operator and accessories varies depending on the overall
dimensions. It is up to the installer to find the most suitable solution.
The drawings refer to the left-side gearmotor. Install the operator on the right, symmetrically.
Corrugated tube laying
Fit junction boxes and corrugates tubes for incoming connections from the junction pit.
The number of tubes depends on the type of system and the accessories you are going
to fit.
Fastening the braces
Establish the point the gate and post braces will be fitted, while respecting the quotas shown on the table.
Post bracket
AX3024
Gate bracket
E
Cable length
Cable type
1 < 15 m
H05RN-F
3G x 1,5 mm
4G x 1,5 mm
2 x 0,5 mm
FROR CEI 20-22
CEI EN
50267-2-1
RG58
AX5024
Cable length
15 < 30 m
2
2
3G x 2,5 mm
2
2
4G x 2,5 mm
2
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
max 10 m