3DGence DOUBLE Manuel d'entretien - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} 3DGence DOUBLE. 3DGence DOUBLE 3 pages. Xy axes calibration

XY axes CALIBRATION OF 3DGENCE DOUBLE
8. If the printing does not comply with these requirements, make following corrections:
a) choose from printer's menu following commands: MENU → ADVANCED → XY CALIB.
b) enter the original dimension to X-axis = 100,
c) enter the measured dimension on X-axis,
d) enter the original dimension to X-axis = 100,
e) enter the measured dimension on Y-axis,
f) save the measurements by choosing: SAVE.
9. Print the model again, then repeat the actions until the measurements oscillate between 99,95 – 100,05
(the tolerance ± 0,05) and the difference between the measurements will be around 0 – 0,05.
05.2018
3DGence DOUBLE | Support: +48 438 98 64 | www.3dgence.com/support