Fig.69 Measurement toothed belt on the X axis
•
Make the timing belt vibrate by vigorously jerking it like a guitar string.
•
Check the voltage value on the tester and read the frequency value.
For a correctly tensioned Timing Belt on the X2 axis, the measured value should be between 71-75 Hz.
If the measured tension value is not within the specified ranges, please contact the 3DGence Technical Support for
assistance.
Measurement of the tension timing belts on the axis Y
3. Move the Y axis to the maximum back position.
4. Place the microphone facing the toothed belt side at the third black mounting hole of the linear guide
counting from the right side of the printer (Fig. 70).
3DGence DOUBLE P255 - maintenance activities | version 07.2021