3DGence DOUBLE P255 유지 관리 매뉴얼 - 페이지 14

{카테고리_이름} 3DGence DOUBLE P255에 대한 유지 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. 3DGence DOUBLE P255 19 페이지.

3DGence DOUBLE P255 유지 관리 매뉴얼
Fig.69 Measurement toothed belt on the X axis
Make the timing belt vibrate by vigorously jerking it like a guitar string.
Check the voltage value on the tester and read the frequency value.
For a correctly tensioned Timing Belt on the X2 axis, the measured value should be between 71-75 Hz.
If the measured tension value is not within the specified ranges, please contact the 3DGence Technical Support for
assistance.
Measurement of the tension timing belts on the axis Y
3. Move the Y axis to the maximum back position.
4. Place the microphone facing the toothed belt side at the third black mounting hole of the linear guide
counting from the right side of the printer (Fig. 70).
3DGence DOUBLE P255 - maintenance activities | version 07.2021