3DGence DT3 Manuel - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} 3DGence DT3. 3DGence DT3 14 pages.
Operation
(4) Check the tank periodically. If the tank level
drops significantly one or two inches due to evapo-
ration, add more water. DO NOT add more cleaning
solution.
(5) If the part or parts will not fit inside the basket
but, will fit inside the tank, the basket can be remo-
ved from the lid by removing the four 10-32 x 3/8"
stainless screws. Reinstall the screws into the lid
for later use.
8. Removing parts
IMPORTANT: Always wear neoprene safety gloves
and eye protection while removing parts from the
tank.
Parts may also be removed by using stainless
steel or plastic tongs. DO NOT use aluminum tongs.
Rinse parts with water until their surfaces do not
feel slippery. Dry parts with paper towels or let
air-dry.
The solution may be used for cleaning additional
parts. Cleaning times are faster with fresh cleaning
solution. Change the solution whenever the water
gets too dark (coffee color) or cleaning times
become noticeably longer.
(continued)
3DGence DT3
3DGence DT3
9. Disposal of soluble solution
Method 1: Dilution
You may dispose of used solution by pouring it
down the drain while simultaneously running tap
water from the faucet. A 5-to-1 ratio (5 parts water
to 1 part solution) is required to reduce the pH
content to typical wastewater standards. Check
local requirements and modify this ratio accordin-
gly.
Method 2: Neutralization
Malic acid may be used to neutralize the pH
content of the solution. Using neoprene safety
gloves and protective eye goggles, slowly add 270
ml of malic acid to the tank before draining. Litmus
paper (or an alternative pH indicator) may be used
to determine if the pH value of the solution is within
local wastewater requirements. An alternative
would be to drain the solution into a container big
enough to handle the full capacity of 3DGence DT3.
At that point mix in 270 ml of malic acid and dispo-
se.
10. Draining the tank
To drain the tank, check to make sure the power
cord is unplugged and that a drain line is securely
connected to the valve. Open the drain valve until
all of the water has emptied. Close the drain valve
when not in use. If neutralizing with malic acid, a
filmy residue may remain in the tank which may be
wiped off with paper towels.
Jet action cleaning
Jet action cleaning