4.3 Description of parts
1) Base plate
2) Gearmotor assembly
3) Motor cover
4) Articulated transmission arm
Optional accessory :
F1001 Straight telescopic arm (for single
gate wings that are 0,5 to 2 m max long).
4.4 Overall dimensions
5 Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
Before installing, do the following:
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• Make sure the path of the electrical cables complies with the command and safety instructions;
• That there is a (soundly secured to the ground) mechanical stop to prevent the gate leaf/gearmotor from over extending
.
•
You may perform internal back up circuit connections, provided you use additional insulation when compared to the other
internal live parts;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
Pillar
1
2
450
*A
Hinge
80
340
End stop
Gate leaf
If distance B is 0 to 300 mm, distance A must
be at least 110 mm.
If distance B is 300 to 380 mm, distance A must
be at least 150 mm.
3
4
182