CAME F1100 Manuel d'installation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} CAME F1100. CAME F1100 15 pages. External automation system with articulated arms for hinged gates
Également pour CAME F1100 : Installation standard (16 pages), Manaul (16 pages), Installation standard (12 pages)

CAME F1100 Manuel d'installation
4.3 Description of parts
1) Base plate
2) Gearmotor assembly
3) Motor cover
4) Articulated transmission arm
Optional accessory :
F1001 Straight telescopic arm (for single
gate wings that are 0,5 to 2 m max long).
4.4 Overall dimensions

5 Installation

Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
Before installing, do the following:
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• Make sure the path of the electrical cables complies with the command and safety instructions;
• That there is a (soundly secured to the ground) mechanical stop to prevent the gate leaf/gearmotor from over extending
.
You may perform internal back up circuit connections, provided you use additional insulation when compared to the other
internal live parts;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
Pillar
1
2
450
*A
Hinge
80
340
End stop
Gate leaf
If distance B is 0 to 300 mm, distance A must
be at least 110 mm.
If distance B is 300 to 380 mm, distance A must
be at least 150 mm.
3
4
182