5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the
current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
5.3 Cable list and minimum thickness
Connection
230 V control panel power supply
230 V motor power supply
Flashing light
Photocell transmitters
Photocell receivers
Accessories power supply
Command and safety devices
Antenna connection
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of
the actual power drawn by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not specified in this manual, please follow the documentation provided
with said products.

5.4 Standard installation

1 - Operator
2 - Control panel
3 - Radio receiver
4 - Antenna
Type of cable Cable length 1 < 10 m
3G x 1.5 mm
3G x 1.5 mm
2
2 x 1.5 mm
FROR CEI
2
2 x 0.5 mm
20-22
2
CEI EN
4 x 1.5 mm
50267-2-1
2
2 x 0.5 mm
2
2 x 0.5 mm
RG58
5 - Flashing light
6 - Selector switch
7 - Photocells
8 - Electric lock
Cable length 10 < 20 m
2
2
3G x 1.5 mm
2
2
3G x 1.5 mm
2
2 x 1.5 mm
2
2 x 0.5 mm
2
4 x 1.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
max. 10 m
Cable length 20 < 30 m
2
3G x 2.5 mm
2
3G x 2.5 mm
2
2 x 1.5 mm
2
2 x 0.5 mm
2
4 x 1.5 mm
2
2 x 1 mm
2
2 x 0.5 mm