ARTRED AR50 Manuel d'utilisation - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} ARTRED AR50. ARTRED AR50 12 pages.

is suddenly abnormal during use, and the squeegee does not absorb water or
the sound of the squeegee is normal, the squeegee cannot absorb water, you
should stop the operation immediately for inspection;
①The water level has risen to the highest position (floating up cut off the wind
path),you will discharge sewage;
Method: Pull the sewage pipe out of the pipe clip, open the pipe cover, drain
the sewage into the sewer, and wash the sewage tank. (right picture)
② If the water level in the dirty water tank is not high and
there is no excess foam, please check the connection
between the suction hose and the hose, which is likely to
be clogged with debris here, and it will return to norma
after being cleared.
③ If the water level in the dirty water tank is not high, but
there is a lot of foam, this means that it is possible for
your cleaning fluid to add too much or the cleaning fluid
you use is a high foam cleaning liquid.
④ If the above three conditions are not, please pull out the suction pipe on
the suction pickup, open the motor of the suction machine, and use your
hand to try whether the suction of the air intake is normal, if the suction is
too small, check whether the suction connecting pipe is blocked.
Method of Replacing Brush Disk:
9.
Loading brush:Place the brush tray to be placed under the brush cover (if
1
using the dial, please put the brush on the dial and then put it), and put down
the brush pedal so that the brush head and the brush holder are basically
opposite. At this time, press the control panel to brush the motor start button.
As the motor rotates, the brush disk will be automatically installed. You can
then start the operation or manually install it. For the unskilled staff, it is
recommended to install it manually.
② Unloading brush:After you finish your work, first raise the brush disc, close
the brush disc switch, the motor stops turning the brush disc by hand, and then
the brush disc can be removed.
Battery replacement method:
10.
① Cut off all button switches and open the sewage tank.
②Release the clamp on the battery, remove the battery connection, and
replace the battery separately.
- 10
-