Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} DOCK LIFEGUARD DOCK LIFEGUARD. DOCK LIFEGUARD DOCK LIFEGUARD 15 pages. Dock warning system

multiple Dock Lifeguard systems to get full coverage on the dock as the metal pilings with act as a return
path to ground for stray electricity, thus not allowing the electricity to travel to the probe install
location. Note: You must have a proper bond from the Dock Lifeguard to the dock safety ground.

Where not to install

Do not install in a location which would inhibit viewing the warning strobe or inside a shed which would
muffle the sound of the warning siren.
Do not install probe directly next to a metal underwater structure such as underwater bracing, sea
anchor cables or steel underwater dampening structures.
Non-Detection Zones
Underwater structures such as sea anchors with metal extruding from them or steel pilings can result in
a non-detection zones for the Dock Lifeguard. Electricity is very lazy and will find the easiest path to
ground which may be one of these structures. It is recommended that you determine if these
structures are around your dock and if so, warn people that swimming in these areas is not safe as these
structures may attract electricity and shield it from getting to the Dock Lifeguard probe and being
detected.