Docking Drawer 161102 Manuel d'installation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Docking Drawer 161102. Docking Drawer 161102 5 pages.

Docking Drawer 161102 Manuel d'installation
Reinstalling the Outlet–
Install the AC/USB charging outlet in the receptacle
box before plugging in the Docking Drawer.
­ ­
­
­
•­­ A fter­the­receptacle­box­has­been­correctly­installed­in­the­
REMINDER: IF THE CABLE ARM GROUND WIRE WAS REMOVED DURING
INSTALLATION, MAKE SURE IT HAS BEEN REATTACHED AND TORQUED
PROPERLY. MAKE SURE THE CIRCUIT BREAKER IS WIRED IN SERIES WITH
THE LINE (BLACK) WIRE AS SHOWN IN THE WIRING DIAGRAM.
•­ ­ F ollow­the­AC/USB­charging­outlet­instructions­(included­in­outlet­packaging)­
and­connect­the­black,­white,­and­green­wires­in­accordance­with­those­
instructions.

Specifications–

Docking­Drawer
­Technical­Specifications:
•­ AC­Power:­125V,­tamper­resistant­NEMA­5-15R­duplex­receptacle.
•­ ­ D C­(USB)­Power:­5.2V,­12.5W­duplex­USB­charging­­ r eceptacle­with­
integrated­­ o n/off­safety­switch.
•­ ­ M ax­rated­current­@­125­VAC:­3A.­Circuit­is­protected­by­5A­pop­­ o ut­
breaker­accessible­from­the­user­side.­Designed­for­charging­personal­
electronic­devices­only.

Wiring Diagrams–

Operation–

•­ ­ I nstructions­specific­to­the­USB­charging­outlet­are­
included­with­the­outlet­itself.
•­ ­ T he­Docking­Drawer­includes­a­5A­resettable­circuit­
breaker.­Breaker­trip­is­indicated­by­the­white­button­
protruding­approximately­3/8"­out­from­the­housing.­
To­reset,­correct­the­source­of­over­current­and­push­
the­white­button­back­in.
back­of­the­drawer­and­(if­applicable)­all­wires­correctly­
reattached,­the­AC/USB­charging­outlet­can­be­installed.­
Receptacle Box Wiring
Green Wire (ground):
green screw
White Wire (neutral):
silver screw
Black Wire (line):
brass screw
5