4. In / Outputs

! Trigger Outputs

Sockets ! are the outputs from the three trigger rows
and the gate row.
" Control
Alongside the four buttons for sequencer control, there
are four corresponding digital control input sockets ".
• Start
:
A signal here starts the sequence.
• Stop
:
A signal here stops the sequence.
• Clock
:
A clock signal here steps through the
sequence. Also called 'step' input.
• Reset
:
A signal here sends the sequence back to
step one.
H
Start and Stop inputs work in trigger mode.
As soon as they sense the rising edge of a
pulse, they produce a momentary signal.
The length of the pulse makes no difference
- a pulse of long duration still just produces a
momentary trigger.
System A - 100
§ CV outputs, control inputs
The two groups of sockets § contain the analog CV
outputs for each row, and the digital control inputs
for the sample-and-hold and slew limiter sections.
The upper group of sockets relates to analog CV row
1, and the lower to analog CV row 2.
• Pre Out
• Post Out
Analog / Trigger Sequencer
Clock (step) and Reset inputs, on the other
hand, work by sensing level: so, for instance,
Reset will always be active (keeping the
sequence at step one) as long as the reset
signal is "high".
:
The control voltages set on the
respective analog CV row are output
here, before (pre) passing through the
slew limiter and sample-and-hold sec-
tions.
: The control voltages set on the
respective analog CV row are output
here, after (post) passing through the
slew limiter and sample-and-hold sec-
tions.
A-155