Indication
Permanently OFF
all relays inactive
Output
due to system
48
error
Two-hand control
not activated
(LED run 2 ON)
or all relays inac-
LED
tive
Run 1
due to
system error
Activation of the
assigned safety
Output
outputs is permis-
58
sible or system
error
all relays inactive
LED
due to system
Run 2
error
Function error Indication
Function errors are indicated by the white LED Run 1 and by output 48;
the white LED Run 2 remains on. Output 58 is ON as long as the error is
pending; it flashes regularly, while waiting for the assigned start signal.
error codes*
1) Normal interruption of function (e.g. Emergency stop)
2) Time error: (e.g. the second two-hand button is not pressed)
3) With gate monitoring: simulation input error (kept pressed for
too long)
4) Error at start input
5) Input error (short-circuit, interruption)
6) Error in the control unit (input or output error detected in
the control unit)
* number of short flashing impulses, followed by a longer space
Special with two-hand control:
When both two-hand buttons of the module are inactive while all other
functions are active and enabled either by autostart or via the start but-
ton, output 48 and the white LED Run 1 are permanently OFF, and out-
put 58 permanently ON.
Pulsing
Permanent ON
Activation of the
one input function
assigned safety
not available
outputs is
permissible
one input function
not available
Activation of
(LED run 2 ON) or
the assigned
system error when
safety
LED Run 2 is OFF
outputs is
or flashing
permissible
Error exists no
one input
more,
function
waiting for
not available
Start input
all relays inactive
due to system
No system error
error
4