d&b audiotechnik 24S-D Manuel - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} d&b audiotechnik 24S-D. d&b audiotechnik 24S-D 14 pages. Xs series
Frequency response correction of the CPL function
Isobar diagram horizontal
Isobar diagram horizontal
8
CPL function
The CPL (Coupling) function compensates for coupling effects
between the cabinet and close boundary surfaces. CPL begins
gradually around 1 kHz, with the maximum attenuation below
400 Hz. To achieve a balanced frequency response, the CPL
function can be set to dB attenuation values between 0 and –9.
Positive CPL values create an adjustable low frequency boost (0 to
+5 dB) at around 65 Hz and can be set when the system is used in
full range mode without subwoofers.
2.4. Dispersion characteristics
The following graphs show dispersion angle over frequency of a
single cabinet plotted using lines of equal sound pressure (isobars)
at –6 dB and –12 dB.
24S
vertical setup
Isobar diagram vertical
24S
horizontal setup,
horn rotated
Isobar diagram vertical
d&b 24S/24S-D Manual 1.1 en