Frequency response correction of the CPL function
Isobar diagram horizontal
Isobar diagram horizontal
8
CPL function
The CPL (Coupling) function compensates for coupling effects
between the cabinet and close boundary surfaces. CPL begins
gradually around 1 kHz, with the maximum attenuation below
400 Hz. To achieve a balanced frequency response, the CPL
function can be set to dB attenuation values between 0 and –9.
Positive CPL values create an adjustable low frequency boost (0 to
+5 dB) at around 65 Hz and can be set when the system is used in
full range mode without subwoofers.

2.4. Dispersion characteristics

The following graphs show dispersion angle over frequency of a
single cabinet plotted using lines of equal sound pressure (isobars)
at –6 dB and –12 dB.