Location of the unit
Clearances to non-combustible materials
There must be a minimum clearance of 150mm at each side of the
appliance. A clearance of 150mm is required at the back of stove (if the
rear wall has a thickness of 200mm or more this measurement can be
reduced to 50mm) A minimum clearance of 150mm is required above the
appliance.
Clearances to combustible materials
There must be a minimum clearance of 450mm at each side and 750mm at
the rear of the appliance from any combustible materials. If using single
wall flue pipe, there must be a clearance of at least 3 times the diameter of
the flue pipe (e.g 125mm diameter pipe = 375mm minimum clearance)
from any combustible materials e.g wooden beam.
Curtains and soft furnishings should be a minimum of 1m away from the
appliance.
Adequate space should be provided for servicing the appliance.
We do not recommend that plasma televisions and expensive artwork are
hung over the fireplace.
Please remember that this appliance has been designed to provide heat
and if installed into a recess enough space should be left around the
appliance to enable the heat produced to rise and escape from the recess
back into the room.
Hearth Requirements
The appliance must stand on a level fireproof hearth with a minimum
thickness of 12mm. The hearth temperature created by this stove is below
100˚C. The hearth must protrude at least 300mm in front of the appliance
and 150mm either side of the appliance.
The appliance shall be installed on a floor with an adequate load bearing
capacity. If an existing construction doesn't meet with prerequisite, suitable