Flue Requirements
The chimney must comply with current Building Regulations. Provision must
be made to provide access for cleaning the appliance, the flue gas
connector and the chimney flue.
The flue must be:
 In sound condition and provide sufficient draft
 Suitable for use with solid fuel burning appliances
 Free from deposits
 Well insulated
 At least 4.5m in height
The flue must not be:
 Shared with other appliances
 Weight bearing on the appliance
 A smaller diameter than the appliance flue collar size (125mm)
Assembly of the unit
The appliance is supplied assembled with the flue spigot in the top exit
position. If you intend to install the appliance using a rear flue connection,
the blanking plate should be swapped over as follows:
 Remove the internal baffle plate
 Remove the blanking plate retaining bar internally.
 Remove the flue spigot from the top exit by removing the securing bolts
and rope seal.
 Refit the rope seal and flue spigot to the rear exit and secure with the
bolts. Seal with fire cement.
 Refit the blanking plate to the top exit using the rope seal and retaining
bar
Maintenance
The chimney should be swept at least once a year together with the flue
pipe connection. Care should be taken to ensure that there is not a build
up of soot on the baffle and in the airways of the appliance.
If the appliance has not been operated for long periods, the flue should be
inspected and swept before use to ensure there are no blockages within
the flue.
The grate should be cleaned regularly and the ashpan emptied daily.
NEVER ALLOW THE ASH IN THE ASHPAN TO OVERFILL ALLOWING ASH TO BE IN
CONTACT WITH THE UNDERSIDE OF THE GRATE. This will overheat the grate
and cause premature wear and distortion.