The RJ-11 input connectors are provided for connection to the Line Sections.
AC power is applied through the fused receptacle on the rear panel. The mating power cord
is supplied. Power requirements are 115/230 VAC, 50/60 Hz.
1.3 Setup
The Model 81096 needs to be setup for the proper IP address for your system as well as the
proper element power ranges for your transmitter. The unit may be addressed using a
crossover cable connected to the Ethernet connector on the rear panel. The initial IP
address of the Model 80196 is 192.168.3.250 and the initial password is "123456". The
password may be changed by using the RS-232 connection and a terminal program.
Connect at 19200,8-N-1 flow control should be set for Xon/Xoff and press enter to access
the set-up menu. To reset the unit to original factory settings, turn the unit off. Press
and hold the reset switch when turning the power on.
Both the forward and reflected power ranges must be set for each port to match the
elements in use. Alarm set points are then set to match the desired trip points for high and
lower power on both forward and reflected channels.
If elements are ordered with the Model 81096, the ranges will be set at the factory on
port 1 and noted on the front of this manual.