Coaxial Dynamics 81096 Buku Petunjuk - Halaman 9

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Alat Ukur Coaxial Dynamics 81096. Coaxial Dynamics 81096 11 halaman.

2.1
Unit Operation
Make sure all connections; adjustments and settings are correct before operation of the unit.
When RF power is present, the unit will operate as a power meter displaying both forward
and reflected power for each port, if they are connected to a line section.
If you add port 2 after the initial setup, you will need to shut down the unit and enter the
power and alarm settings before connecting the new line section cable to the Model 81096.
(See section 1.3 Setup)
When the reflected power rises above the preset level (or when forward power drops below
the preset level) the Model 81096 will sound the alarm. If the systems are connected to an
interlock circuit the protected unit will be shutdown and the display will hold the fault
condition until the unit is reset. To reset the unit, press the reset button until the display
indicates "Sending E-Mail". Note: this resets only the Model 81096. The fault needs to
be corrected before restarting the transmitter.
2.2
Load Adjustments
If adjustment at the load is required without interruption by the Model 81096, set the alarm
points outside the range expected to be measured.
Model 81096

SECTION 2 - OPERATION

- 7 -
8/2019