Door Controls DC One Panduan Instalasi - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Sistem pembukaan pintu Door Controls DC One. Door Controls DC One 20 halaman. Automatic sliding door retrofit drive assembly

13. MENU DISPLAY SCREENS

Pressing the up button will cycle through the menu in the following order.
Factory default settings are shown, following a reset.
Turning the parameter adjustment knob will change the values for that setting.
Door Position
DOOR POSITION
act sf ro bo
This is a status only screen that gives the following information:
Encoder Counts – shows the actual encoder count relative to door position
Encoder Pulses – toggles between upper and lower case as encoder pulses are received
Status – toggles between upper and lower case as status changes
State – shows the state of the controller
Life Cycle Counter
LIFE CYCLE COUNT
Indicates the total number of door cycles on the control
Non-resettable
Trip Cycle Counter
TRIP CYCLE COUNT
Indicates the number of cycles since the trip counter was last reset
DC One V3 Installation Manual
M-0015 REV 06222017 P10
00258
0
X Y
Status
act/ACT – Activation
o
sf/SF – Safety
o
ro/RO – Reduced open
o
bo/BO – Breakout
o
0 – Closed
o
1 – Opening
o
2 – Open Deceleration
o
3 – Open Check
o
4 – Open
o
5 – Closing
o
6 – Close Deceleration
o
7 – Close Check
o
B – Boost Mode
o
L – Learn Mode
o
O – Obstruction
o
00000000
00000000
Encoder
Counts
Encoder Pulses
Page 7 of 15