13. MENU DISPLAY SCREENS
Pressing the up button will cycle through the menu in the following order.
Factory default settings are shown, following a reset.
Turning the parameter adjustment knob will change the values for that setting.
Door Position
DOOR POSITION
act sf ro bo
This is a status only screen that gives the following information:
Encoder Counts – shows the actual encoder count relative to door position
•
Encoder Pulses – toggles between upper and lower case as encoder pulses are received
•
Status – toggles between upper and lower case as status changes
•
State – shows the state of the controller
•
Life Cycle Counter
LIFE CYCLE COUNT
Indicates the total number of door cycles on the control
•
Non-resettable
•
Trip Cycle Counter
TRIP CYCLE COUNT
Indicates the number of cycles since the trip counter was last reset
•
DC One V3 Installation Manual
M-0015 REV 06222017 P10
00258
0
X Y
Status
act/ACT – Activation
o
sf/SF – Safety
o
ro/RO – Reduced open
o
bo/BO – Breakout
o
0 – Closed
o
1 – Opening
o
2 – Open Deceleration
o
3 – Open Check
o
4 – Open
o
5 – Closing
o
6 – Close Deceleration
o
7 – Close Check
o
B – Boost Mode
o
L – Learn Mode
o
O – Obstruction
o
00000000
00000000
Encoder
Counts
Encoder Pulses
Page 7 of 15