Door-Gard 2000e Instalasi & Pemrograman - Halaman 4

Jelajahi secara online atau unduh pdf Instalasi & Pemrograman untuk Papan tombol Door-Gard 2000e. Door-Gard 2000e 7 halaman.

Door-Gard 2000e Instalasi & Pemrograman
Changing the Master Code
The fi rst step in setting up your keypad is to enter program mode and
change the master code. The default master code is 1234.
1.
Enter Program Mode
Press: 99 # master code ✱
2.
Change Master Code
Press: 1 # new master code ✱ repeat code ✱
3.
Exit Program Mode
Press: ✱
Programming a Supervisor Code
Use the following command sequence to program a supervisor code,
which is stored user location 2. The supervisor is only allowed to add,
delete and disable users.
1.
Enter Program Mode
Press: 99 # master code ✱
2.
Change Supervisor Code
Press: 2 # supervisor code ✱ repeat code ✱
3.
Exit Program Mode
Press: ✱
Selecting Secured Series Front End Mode
To select Secured Series Front End Mode, use the following steps:
1.
Enter Program Mode
Press: 99 # master code ✱
2.
Select Secured Series Front End Mode
Press: 1032 # 0 # 2 # ✱ ✱
3.
Exit Program Mode
Press ✱
Selecting Wiegand Front End Mode
To select Wiegand Front End Mode, use the following steps:
1.
Enter Program Mode
Press: 99 # master code ✱
2.
Select Wiegand Front End Mode
Press: 1032 # 0 # 1 # ✱ ✱
3.
Exit Program Mode
Press ✱
Selecting Standalone Mode
Standalone Mode is the default operating mode. If you've changed
the operating mode and want to revert back to Standalone Mode, use
the following steps:
1.
Enter Program Mode
Press: 99 # master code ✱
2.
Select Standalone Mode
Press: 1032 # 0 # 0 # ✱ ✱
3.
Exit Program Mode
Press ✱
4
(Yellow LED Flashes Slowly)
(Yellow LED Flashes Slowly)
(Yellow LED Stops Flashing)
(Yellow LED Flashes Slowly)
(Yellow LED Flashes Slowly)
(Yellow LED Stops Flashing)
(Yellow LED Flashes Slowly)
(Yellow LED Flashes Slowly)
(Yellow LED Stops Flashing)
(Yellow LED Flashes Slowly)
(Yellow LED Flashes Slowly)
(Yellow LED Stops Flashing)
(Yellow LED Flashes Slowly)
(Yellow LED Flashes Slowly)
(Yellow LED Stops Flashing)
2000e & 2000eM Keypad Installation & Programming

Programming Users

(Standalone Mode Only)
The unit can hold up to 500 users. Codes are 1 to 10 digits in length.
Command/Action
Add Standard User (short) user location # code ✱ code ✱
Add Standard User with
Specifi c Unlock Time
Add Enhanced User
Add User to Trigger
Specifi c Outputs
(Lock, OUT2-10)
Disable User
Delete User
User Types
(Standalone Mode Only)
User Types
Description
A toggle user latches the Lock Output like an
on/off switch. When you enter the code the fi rst
Toggle User (0)
time, the Lock Output is activated and remains
activated until you enter any toggle code.
This user type is a standard timed user that
activates the lock output for the time duration
Standard User (1)
programmed with command 11 or with the
master code.
A Locks Out User is used to lock out users
from the keypad. After entering a lock out
code, users in a higher user location are
Lockout User (3)
denied access. To clear a lock out, enter the
same lock out code you used to enter lock
out mode.
This user code can only be used once. After
entering the code, the user is deleted from
memory. To verify a single use code is still
Single Use Code (5)
programed, enter 5 # code ✱. If the code
wasn't used, the green LED fl ashes for ½ a
second.
An emergency user operates as a standard
Emergency User (7)
timed user, with one exception, it can't be
Locked Out by a lock out user.
The duress user is another type of
emergency user. This user activates both the
Duress User (8)
Lock and Duress Outputs. You would use
this code if you wanted to activate an alarm,
as well as gain entrance through the door.
This user type is one half of a two-part user
combination. When you enter a Type A user
code, you must enter a Type B user code to
Two-Part User
gain access through the door. After entering
Type A (9)
the code the bi-color LED alternates red and
green. You have 15 seconds to enter the
second code.
This user type is the second half of a
Two-Part User
two-part user combination. After entering a
Type B (10)
Type B code you must enter a Type A code
to gain access through the door.
Keys to Enter/Details
unlock time # user location #
code ✱ code ✱
60 # user type # user location #
code ✱ code ✱
59 # outputs # user location # code
✱ code ✱ (1 = Lock, 2 = OUT2,
3 = OUT 3, Etc)
56 # 0/1 # user location # ✱ ✱
(0 = enabled; 1 = disabled)
user location # ✱ ✱
6-104402 X2