Stand-Alone Wiring
1. Connect 12-24 Volt AC or DC power to terminals 1 and 2. If DC power is used, terminal 1 is NEGATIVE and
terminal 2 is POSITVE. Use minimum18 AWG wire to power the receiver.
2. Connect the receiver relay contacts to the device to be activated. Terminal 3 is NORMALLY OPEN (N.O.),
terminal 4 is NORMALLY CLOSED (N.C.) and terminal 5 is COMMON (C). Use 18 AWG wire to connect the
receiver relay contacts to the operating device.
Wiegand Wiring
Terminal 2 is INPUT POWER (12-24 V), terminal 6 is Wiegand COMMON, terminal 7 is Wiegand DATA 0, and terminal 8 is
Wiegand DATA 1. Use 22 AWG shielded wire, maximum 200 feet, for Wiegand wiring. Connect these terminals to the
corresponding terminals on the Wiegand controller. Refer to the Wiegand controller installation manual 1815, 1817 or
1818 for detailed wiring information.
Master Transmitter Programming
The 8059 receiver master transmitter fuction allows you to program up to 4 (four) master transmitters. When a "Master
Transmitter" is activated, the receiver will automatically go into learn mode allowing additional transmitters to be pro-
grammed into the receiver memory.
NOTE:
Master transmitters are not intended to be used as regular transmitters. Keep all master transmitters
in a safe place.
Press and hold the receiver programming button and follow the flashing LED sequence as shown.
1
2
3
7
The receiver is now in master transmitter program mode. Select a transmitter to designate as a master transmitter
press the button; the button, facility code and transmitter number are programmed into the receiver as a master
transmitter. The button, facility code and transmitter number must match in order to put the receiver into the
regular learn mode.
Transmitter Programming
1. Press and hold the receiver programming button or the "Master Transmitter" button until the programming
LED flashes once (about 2 seconds), and release. The programming LED will flash once every second
indicating that you are in the transmitter programming mode.
2. While the programming LED is flashing, activate the transmitter(s) so that the receiver can record the
transmitter code(s) into memory. A maximum of 80 transmitter codes can be stored in the receiver memory.
3. When all the transmitter have been programmed, wait ten (10) seconds, the programming LED will
come on for three (3) seconds and then go out indicating that the programming sequence has ended.
Wiegand Programming
At least one transmitter code must be programmed into the receiver memory, allowing the receiver to respond to
the facility code and transmitter button that will be used. This step is necessary so that the receiver knows which
button to respond to. For example, if a two (2) button transmitter code is programmed into the receiver using
button 2, the receiver will only respond to transmitter codes initiated by button 2. To have a receiver respond to
both buttons, you can program the transmitter code into the receiver twice, using button 1 and 2. If using more
than one facility code, or if the receiver is to respond to different transmitter buttons, simply program additional
transmitters, refer to Stand-Alone Programming.
NOTE:
The factory setting is for 26-bit and requires a facility code match. You need to program a transmitter into
the receiver, refer to Stand-Alone Programming.
Receivers manufactured prior 11/98 (board program chip REC 2) do not have the programming capability to
ignore facility codes. These receivers will always check the facility code.
4
4
8
4
5
6