Section 11. Troubleshooting
When there is an error condition, "ERROR" flashes on the display along with the error code.
Fault Indication
NO FLOW
(NO F)
LOW SALT
(LO S)
Display Blank
Low/No Chlorine
in pool
Clock loses time when main
power is removed
Timer is set to OFF in the
TMR menu
Table 5. Troubleshooting
Installation Manual
Possible Cause
•
Pump turned off/disconnected or valves
closed
•
Blue wire disconnected from cell
•
Salt level in pool has dropped too low
•
Pool water temperature is low
•
Cell has calcified
•
Cell has failed
•
No power to controller
•
Fuse blown
•
Cables not connected to cell
•
Timer period too short
•
Chlorine output level too low
•
Filter needs backwashing
•
pH too high
•
Pool stabiliser (cyanuric acid) too low
•
Salt level too low
•
Clock power backup failed
•
The timer has been turned off
Solution
•
Ensure valves/pump ON
•
Connect BLUE sense wire to cell
•
Take sample of water to retailer and check salt level - add
salt as recommended.
•
Add salt and turn chlorinator output down until the water is
warmer.
•
Clean the cell.
•
Call for service
•
Plug in controller and ensure main power available
•
Have a service technician replace fuse (2A slow blow)
•
Connect cables
•
Increase timer period (particularly during summer)
•
Increase chlorine output
•
Backwash filter
•
Balance pH level to 7.4 - 7.6
•
Increase stabiliser between 30 - 60 ppm.
•
Increase salt to above 6000 ppm
•
Call a technician
•
Use AUTO
to turn the timer back on. Adjust timer start
and stop times to suit.
13