Astralpool E Series 매뉴얼 - 페이지 13

{카테고리_이름} Astralpool E Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Astralpool E Series 16 페이지. Saltwater chlorinator
Astralpool E Series에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (12 페이지)

Astralpool E Series 매뉴얼
e series saltwater chlorinator

Section 11. Troubleshooting

When there is an error condition, "ERROR" flashes on the display along with the error code.
Fault Indication
NO FLOW
(NO F)
LOW SALT
(LO S)
Display Blank
Low/No Chlorine
in pool
Clock loses time when main
power is removed
Timer is set to OFF in the
TMR menu
Table 5. Troubleshooting
Installation Manual
Possible Cause
Pump turned off/disconnected or valves
closed
Blue wire disconnected from cell
Salt level in pool has dropped too low
Pool water temperature is low
Cell has calcified
Cell has failed
No power to controller
Fuse blown
Cables not connected to cell
Timer period too short
Chlorine output level too low
Filter needs backwashing
pH too high
Pool stabiliser (cyanuric acid) too low
Salt level too low
Clock power backup failed
The timer has been turned off
Solution
Ensure valves/pump ON
Connect BLUE sense wire to cell
Take sample of water to retailer and check salt level - add
salt as recommended.
Add salt and turn chlorinator output down until the water is
warmer.
Clean the cell.
Call for service
Plug in controller and ensure main power available
Have a service technician replace fuse (2A slow blow)
Connect cables
Increase timer period (particularly during summer)
Increase chlorine output
Backwash filter
Balance pH level to 7.4 - 7.6
Increase stabiliser between 30 - 60 ppm.
Increase salt to above 6000 ppm
Call a technician
Use AUTO
to turn the timer back on. Adjust timer start
and stop times to suit.
13