Accessing Installer Setup
Touch Screen to bring up Main page
Press Dorani Symbol to show parameters
Press and Hold Door release button
Monitor Address Programming
Set Monitor Address by typing the numbers below and pressing OK.
ON EACH MONITOR – EACH MONITOR MUST HAVE A DIFFERENT ADDRESS
Monitor
Master
Sub 1
Sub 2
Sub 3
Note:
The system is designed for 2 monitors to alight on intercom call, all monitors will ring
and can answer the call if desired.
3
and 4
monitors may alight on call if programmed, this is site dependant based on
rd
th
cable lengths and types. If a lower quality video image is displayed, turn off monitors.
Door Station Address Programming
For when more than 1 door station is installed. The door station you set this too will
then enable the monitor to view this door station.
NON KEYPAD DOOR STATIONS:
Remove front fascia cover using screws on back
The next steps need to be done QUICKLY
Power up Door station whilst holding TOP (B) button in for 3 seconds. The system
should beep and flash)
Press and hold BOTH buttons for 3 seconds, the system should beep and the light should
go out.
Press TOP button ONCE (it should beep 1 time)
Press TOP button TWICE (it should beep 2 times)
Press TOP button THREE TIMES (it should beep 3 times)
Press TOP button FOUR TIMES (it should beep 4 times)
Power off once completed OR wait 10 seconds without pressing any buttons
INSTALLER PROGRAMMING
Address
8000
8001
8002
8003
until Installer Setup keyboard is viewed
On/Off Display on Call
8006/8007
8006/8007
8006/8007
8006/8007
5
=
Door 1
=
Door 2
=
Door 3
=
Door 4