OPERATION
1. Insert the key into the cylinder and turn clockwise to arm unit. Rotate to initial position to remove key.
2. Arming time is of 15 seconds, during which the LED flashes green every 1.5 seconds.
3. A brief sound will indicate that the alarming time is complete. When armed the LED will flash red every 15 seconds.
4. Turn the key counterclockwise to disarm.
5. Changing the battery:
A beep will sound every 15 seconds to indicate that battery is low. This cannot be shut down by disarming the unit
and the sound will stop only when battery is changed.
6. To change the battery.
A. Remove end cap and loosen or remove mounting bracket.
B. Remove cover plate.
C. Change Battery.
D. Reassemble.
OPTIONS
Mode select
switches
MODE SELECT SWITCHES
Option
Rearm time
If switch No. 1 is off, AL device re-arms with no delay.
Set switches No. 2 and 3 for auto reset alarm time.
Auto reset time
Three setting options: 1.5, 3 or 5 minutes.
NOTE: The default configuration setting for alarm sound is set for 5 minutes
before rearming.
End Cap
Bracket
Cover Plate
End Cap
Bracket Screws
Function
LED Indicator
Mortise Cylinder
End Cap
End Cap
Screws
9 Volt
Battery
Factory settings shown
Minutes
Switch No. 2
Switch No. 3
4
+
+
-
-
Make sure polarity
is correct
Rearm time
Auto reset time
On
On
On
AUTO RESET TIME
1-1/2
3
5
off
on
on
on
on
off
DX-KA3-INST 2020-06
infinite
off
off
WD-OD002(668)