32 FLOOR ELEVATOR SYSTEM

This configuration is used when connecting to an elevator system of up to 32 floors. This
consists of two H1000 control panels, designated as a master panel and a slave panel.
RS485 Communication wires to host computer using Cansec
communication line driver, e.g. CLAUSB, Canlan or Air-485
Master
Master Panel:
Controls floor 1 to 16
Master and slave RS485 communication wires
Master Panel
1. Dipswitch Settings:
OPT1: ON
OPT2: ON
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
3. Address Setting:
Panel address is set to 1 in this example
Slave 1 Panel:
Controls floor 17 to 32
1. Dipswitch Settings:
OPT1: ON
OPT2: OFF
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
3. Address Setting:
Panel address is set to the same as Master Panel
H1000 Elevator Control
Installation Guide
Slave 1
Slave 1 Panel
Page 6 of 20
October 2015 • Rev. 1.7