Cansec H1000 Instrukcja instalacji - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Kontroler Cansec H1000. Cansec H1000 20 stron. Elevator control

32 FLOOR ELEVATOR SYSTEM

This configuration is used when connecting to an elevator system of up to 32 floors. This
consists of two H1000 control panels, designated as a master panel and a slave panel.
RS485 Communication wires to host computer using Cansec
communication line driver, e.g. CLAUSB, Canlan or Air-485
Master
Master Panel:
Controls floor 1 to 16
Master and slave RS485 communication wires
Master Panel
1. Dipswitch Settings:
OPT1: ON
OPT2: ON
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
3. Address Setting:
Panel address is set to 1 in this example
Slave 1 Panel:
Controls floor 17 to 32
1. Dipswitch Settings:
OPT1: ON
OPT2: OFF
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
3. Address Setting:
Panel address is set to the same as Master Panel
H1000 Elevator Control
Installation Guide
Slave 1
Slave 1 Panel
Page 6 of 20
October 2015 • Rev. 1.7