BOLTON KF-SP-1 Panduan Pemasangan & Pengoperasian - Halaman 6

Jelajahi secara online atau unduh pdf Panduan Pemasangan & Pengoperasian untuk Rentang BOLTON KF-SP-1. BOLTON KF-SP-1 13 halaman. Stock pot range

LEGORIENTATION
LEGS
LEGS

GAS PRESSURE REGULATOR INSTALLATION

Gas regulator pressure is preset at 5" Water Column (W.C.) for natural gas, and 10"W.C.
For propane gas. Minor adjustments maybe required based on site specific gas pressure.
Install the regulator as close to the stock pot on the gas supply line as possible. Make sure that
the arrow on the underside of the regulator is oriented in the direction of gas flow to the stock pot
(Fig. 3) and the regulator is positioned with the vent plug and adjustment screw upright(Fig.4).
Fig.3
Fig.4
The minimum supply pressure (up stream of the regulator) should be 7-9"W.C. for natural gas
and 11-12" W.C. for propane gas. At no time should the hot plate be connected to supply
pressure greater than ½ psig (3.45kPa) or 14" W.C.
LEVELING
The Stock pot Range is equipped with legs. Turn the feet at the bottom of the legs in or out to
level the Stock pot Range in the final installed location.

VENTILATION HOOD

The stock pot should be installed under a suitable ventilation hood. For safe operation and
proper ventilation, keep the space between the stock pot and vent hood free from any
obstructions.
6