GAS CONNECTION

The data plate on the rear of the stock pot indicates the type of gas your unit is equipped to burn.
DO NOT connect to any other gas type.
NOTICE
Gas supply connections and any pipe joint compound must be resistant to the action
of propane gases.
Purge the supply line to clean out any dust, dirt, or any foreign matter before connecting the line
to the unit.
Codes require that a gas shut-off valve be installed in the gasline ahead of the stock pot. The
gas supply line must be at least the equivalent of ¾ " iron pipe.
A pressure regulator is supplied and must be installed outside of the broiler when making the
gas supply connection. Standard orifices are set for 5"WC (Water Column) for Natural Gas
1
" pipe tap on the burner manifold for checking
10"WC (Water Column) for Propane. Use the
/
8
pressure.
Make sure the gas piping is clean and free of obstructions, dirt, and piping
compound.
An adequate gas supply is necessary. Under sized or low pressure lines will restrict the volume
of gas required for satisfactory performance. A minimum supply pressure of 7" W.C. for natural
gas and 11"W.C. for propane gas is recommended. With all units operating simultaneously,
the manifold pressure on all units should not show any appreciable drop.
When testin the gas supply piping system, if test pressures exceed ½ psig (3.45kPa), the stock
pot and its individual shut off valve must be disconnected from the gas supply piping system.
When test pressures are ½ psig (3.45kPa) or less,the stock pot must be isolated from the gas
supply piping system by closing its individual manual shut-off valve during any pressure testing
of the system.
Prior to lighting, check all joints in the gas supply line for leaks. Use
soap and water solution. Do not use an open flame.

OPERATION

The stock pot range and its parts are hot. Use care when operating,
cleaning or servicing the stock pot range.
CONTROLS
The burner is in two sections, controlled by two heavy duty infinite control valves. The center
"Star" section (Fig.6) is on separate burner with an input of 40,000BTU/hr. It is controlled by
the right burner valve knob. The outer circle of the burner (Fig. 6) is the other separate
40,000BTU/hr input burner, controlled by the left burner valve knob.
These two separate burners provide heat flexibility.With one burner off and the second burner
set low, up to both burners full on, you can move from low simmer on up to 80,000 BTU/hr input.