Dormakaba 8956 Panduan Petunjuk Instalasi - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Sistem interkom Dormakaba 8956. Dormakaba 8956 10 halaman. Emf surface applied closer (no detector)
dormakaba 8900 EMF Installation Instructions
3
Adjustments
3.1 Adjust closing speeds: sweep, latch, backcheck, delayed action
Fig.7
Backcheck
Delayed action
3.2 Adjust spring force
Fig.8
8916
8956
8900 EMF
Latch
Sweep
Sweep
Latch
NOTE: Delayed action is
optional
8916:
Increase
8956:
Decrease
NOTE:
DO NOT ADJUST SPRING LOWER THAN SIZE 3.
Door width
Max door
Closer size
weight (lbs)
Interior
4
125
2'6"
5
150
3'
6
200
3'6"
6
200
3'6"
6+
250
4'
08281000
Adjustments: closing speeds
Backcheck
Delayed action
positioning valve
Backcheck
intensity
Decrease
Increase
Increase
Decrease
Supplied with a size 3 spring setting
Supplied with a size 6 spring setting.
Full turns
0
+8
+16
0
+6
Adjustments: spring force
Sweep & Latch
Speed
Backcheck &
Delayed action
03-2020
7