Dormakaba 8956 Manual de instruções de instalação - Página 7
Procurar online ou descarregar pdf Manual de instruções de instalação para Sistema de intercomunicação Dormakaba 8956. Dormakaba 8956 10 páginas. Emf surface applied closer (no detector)
dormakaba 8900 EMF Installation Instructions
3
Adjustments
3.1 Adjust closing speeds: sweep, latch, backcheck, delayed action
Fig.7
Backcheck
Delayed action
3.2 Adjust spring force
Fig.8
8916
8956
8900 EMF
Latch
Sweep
Sweep
Latch
NOTE: Delayed action is
optional
8916:
Increase
8956:
Decrease
NOTE:
DO NOT ADJUST SPRING LOWER THAN SIZE 3.
Door width
Max door
Closer size
weight (lbs)
Interior
4
125
2'6"
5
150
3'
6
200
3'6"
6
200
3'6"
6+
250
4'
08281000
Adjustments: closing speeds
Backcheck
Delayed action
positioning valve
Backcheck
intensity
Decrease
Increase
Increase
Decrease
Supplied with a size 3 spring setting
Supplied with a size 6 spring setting.
Full turns
0
+8
+16
0
+6
Adjustments: spring force
Sweep & Latch
Speed
Backcheck &
Delayed action
03-2020
7